Zhengzhou Zhongpai Launches New Ion Chromatograph

Zhengzhou Zhongpai Launches New Ion Chromatograph ICS-2000 is a new-generation ion chromatography system introduced by the United States Dai'an Company, which brings ion chromatography technology to a new level. ICS-2000 is the world's first chemical reagent-free ion chromatography (RFIC) equipped with a fully automatic eluent generator, including a high-precision double-plunger pump, an eluent generator, and a conductivity detector. With a temperature-controlled conductivity cell and a heated oven where columns and suppressors can be placed, the ICS2000 ion chromatograph can be compatible with any type of suppressor technology and analytical column from Diane.

Analytical pump and conveyor type: Tandem double-piston reciprocating pump, microprocessor controlled stroke, variable speed construction: chemically inert, non-metallic PEEK pump head and flow path PH: 0-14 aqueous solution and reversed solvent compatible control mode : Through the front panel or through chameleon software full control; TTL or relay switch selectable maximum operating pressure: 35Mpa (5000psi)

Pressure fluctuation: <1.0%

Flow rate range: 0.05-5.0 mL/min in increments of 0.01;

Flow accuracy: <0.1%

Flow accuracy: ±0.1%,

Piston seal cleaning: Double pump head, continuous cleaning pressure alarm limit when connecting washing liquid: upper limit 0-35Mpa or 0-5000psi in one unit increment (MPa or psi); lower limit can be set one unit lower than the upper limit.

Vacuum Degassing (Optional): Automatic Column Heating Operating Temperature Range: Environment +5°C to 60°C

Temperature stability: ±1°C

Temperature accuracy: ±2°C (at 40°C)

Eluent automatic generator concentration range: 0.1-100 mM

Flow rate range: 0.1-3.0mL/min

Maximum operating pressure: 21Mpa (3000psi)

Maximum solvent concentration: Anion: 25%Mathanol; Cation: Solvent-free conductivity detection circuit and flow cell type: Microprocessor - Digital signal processor Linearity: 1% at 1mS Resolution: 0.00238nS

Detection range: digital mode 0-15000μS;

Filter: start time from 0 to 10 seconds, user selectable temperature compensation: fixed at 1.7% for 1°C

Conductivity cell temperature control temperature range: environment +7°C to 55°C

Temperature stability: ≤0.01°C

Conductivity Cell Electrode: Passivated 316 Stainless Steel Conductive Cell Body Material: Chemically Inert Polymeric Material Conductance Cell Volume: <1 μL

Chi-plus heat exchanger: low differential maximum pool operating pressure: 10MPa

Suppressor control power supply:

AESR, 0-150mA, 1mA increments;

SRS, 0-500mA, 1mA Incremental Physical Specifications Power Supply: 100-240V AC, 50/60Hz (Automatic sensing and regulation)

Voltage range: 90-265V AC, 47-63Hz

Instrument operating temperature: 4-40°C (40-104°F)

Operating Humidity Range: 5-95% Relative Humidity, Non-condensing Control Mode: Controlled by chameleon software, TTL or delay switch can be selected. Two delayed outputs, two TTL outputs, four programmable input USB communication ports: One input, two fixed USB input ports Leak detection: built-in, optical sensor size (h × w × d) 22.1in × 8.8in × 21in; 56.1cm x 22.4cm x 53.3cm

Weight: 54 lbs, 24.5 kg AS40 Autosampler Specifications Vial Size and Texture: 0.5mL or 5mL Vial, Polyvial

Sample capacity: 11 trays 6x5mL or 8x0.5mL

Minimum liquid supply: 0.5mL bottle: 0.17mL/time 5mL bottle: 1.7mL/time per bottle Injection time: 1, 2 or 3

Injection method: Loop: Rapid injection (about 4 mL/min)

Concentration: 0.4mL/min (0.5mL bottle) under 690kPa (100psi) back pressure

Or 0.1mL/min (5mL bottle)

Voltage: 90-165Vac, 47-63Hz

Volume: 28.7X36.3X44.5cm (11.3X14.3X17.5in.)

Weight: <8.9kg (<195 lb)